Product Name: Double Channels Loop Detector for Parking Management Systems-Vehicle Detector
Category: Infrared Sensor
Keywords: Vehicle Loop Detector, Double Channel Detector, Electric Barrier Gate, Parking Sensor, Car Parking Sensor, Traffic Barrier, Driveway Vehicle Detection, Parking Barrier, Automatic Barrier, Truck Scale Detector, Boom Gate Detector, Access Control, Loop Sensor, Barrier Safety Sensor, Underground Loop Coils, Automatic Gate, Inductive Loop Sensor, Loop Detector, Inductive Loop, Road Barrier
Description: The Double Channels Loop Detector for Parking Management Systems is a highly dependable and efficient solution, tailored to meet the stringent demands of vehicle detection in parking lots, driveways, and access control systems. With its dual-channel configuration, this detector ensures exceptional accuracy and performance. It seamlessly integrates with electric barrier gates, boom gates, and automatic barriers, rendering it versatile for a myriad of applications. The advanced inductive loop sensor technology guarantees precise vehicle detection, while the robust underground loop coils assure long-term durability and reliability. Elevate the safety and operational efficiency of your parking facility with this state-of-the-art vehicle detector from Shenzhen Jutai Comm Co., Ltd.
Color |
White/Green |
Voltage |
12-24AC/DC 110-240AC |
OEM |
Yes |
JUTAI LD200/202 double channels vehicle loop detector series, equipped with a sophisticated direction recognition function, is perfectly suited for numerous single-channel entry and exit scenarios.
Connections Of Electric Barrier Gate Parking Management Equipment Parking System
Indicates And Switch Of Electric Barrier Gate Parking Management Equipment Parking System
Power Led: RED power LED indicates 'Power ON'
CH1 Detecting Led: Continuously On: Signals vehicle detection.
Blinking slowly: Indicates loop is short-circuited or the number of twists after the loop is insufficient.
Blinking fast: Indicates loop is open-circuited or there are too many twists after the loop.
CH2 Detecting Led: Continuously On: Signals vehicle detection.
Blinking slowly: Indicates loop is short-circuited or the number of twists after the loop is insufficient.
Blinking fast: Indicates loop is open-circuited or there are too many twists after the loop.
Sensitivity Selection
Sensitivity and frequency of the loop can be finely adjusted using the 7-way dip switch and 10-way dip switch.
Users can choose from 8 different settings by configuring the dip switches to various modes as specified in the dipswitch setting tables below. Dip switch 6, 7, and 8 control CH1 sensitivity selection, with 0.8 being the least sensitive and 0.015 being the most sensitive.
Dip switch 3, 4, and 5 control CH2 sensitivity selection, with 0.8 being the least sensitive and 0.015 being the most sensitive.
3. Switch 1=S1: Channel 1 Loop Function Selection (10-way dip switch)
(1)(Switch 1) DIP 1 & DIP 2 Special Sensitivity Increase for Both Trailer (Both Channels).
(2)(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2 Setting Special Functions (Mode 1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode, two loop detection are separated)
(3)(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4 & D5 Setting CH1 and CH2 Sensitivity Selection (Eight Levels Choices).
(4)(Switch 1=S1) Configure Frequency: D9 & D10 and (Switch 2=S2) D6, D7 settings allow frequency tuning from 20 KHz to 100 KHz, ensuring optimal performance.
* Reset Button: Important Notice: Each time you adjust the Dip switches, you must reset the LD-200 to apply the new settings effectively.
Loop Installation: Enhance your Electric Barrier Gate Parking Management System with precise loop installations for seamless parking control.
The loops are securely sealed using a 'quick-set' black epoxy compound or hot bitumen mastic, perfectly blending with the roadway surface to ensure durability and reliability.
During installation, ensure that the product plug and socket maintain a vertical orientation for optimal functionality.
Application: Perfect for Electric Barrier Gate Parking Management Systems, our equipment enhances efficiency and security.
The JUTAI LD200/202 Double Channels Vehicle Loop Detector Series, featuring direction recognition, is ideal for various single-channel entry and exit scenarios, offering unmatched precision and reliability.
JUTAI LD200/202 double channels loop detector seamlessly integrates with JUTAI One Door Controller (Model: AC-11), JUTAI Gate Barrier (Model: BR-110), and JUTAI Long Range RFID Reader (Model: PUHF-9). Combined with high-temperature-resistant loop coils (Model: JTHT-11), it delivers exceptional performance in single-channel entry/exit access control systems.
Working Principle: Learn how Electric Barrier Gate Parking Management Systems function for optimal parking management.
When a vehicle approaches from outside to enter a community or parking lot, the two loop coils are simultaneously activated. The JUTAI Double Channels Loop Detector (LD-200/202) triggers the UHF reader at the entry point. The reader reads the card ID and sends it to the controller (AC-11) via Wiegand output. Upon validation, the controller outputs a relay signal to open the gate barrier, allowing vehicle entry. After the vehicle passes through, the barrier arm automatically lowers. For safety and anti-smashing, this setup works in conjunction with the JUTAI Single Channels Loop (LD100/102). Due to the Direction Recognition Function of LD200/202, subsequent UHF reader signals will not be triggered again, thereby recording only ENTRY logs in the system.
Conversely, when a vehicle exits the community or parking lot, the inside UHF reader is triggered by the LD200/202. The reader reads the card and sends the ID to the controller, which then validates it and outputs a relay signal to open the gate barrier. After the vehicle exits, the barrier arm automatically lowers. Again, for safety and anti-smashing, the system works with the JUTAI Single Channels Loop (LD100/102). The Direction Recognition Function of LD200/202 ensures that the system only records EXIT logs without double-triggering signals when the vehicle passes another UHF reader at the exit.
The JUTAI LD-200/202 Double Channels Loop Detector can also function as two independent single-channel loop detectors. This configuration is ideal for standard one-in, one-out parking lots, each with its own barrier and long-range reader. One loop coil triggers the reader to read the card, while the other coil performs the barrier anti-smashing function. Utilizing the independent working mode function of LD200/202 can reduce hardware costs, making it an economical choice for efficient parking management.