Features
Anti-rush design. At the first operation after each power on, the motor runs in slow motion to the limit point throughout the process to avoid rushing out of the limit. When the door reaches the limit point, the motor can only be operated by pressing the button in the opposite direction to prevent the limit from being broken out. (Notice: It has the power-off protection function when in place, and the motor only moves in the opposite direction when repowered).
Master-slave mode is available. Two motors with the same control board on each can work synchronously. In this mode, an infrared, ground sense, automatic door close, and other functions are synchronized. Attention: Infrared, ground sense must be connected to the master motor.
Motor runtime protection. To prevent the motor from running during the travel failure, the control board will automatically learn the motor running time without manual setting, and 10s will be added automatically as the time margin.
Auto-close function. Time can be set from 1s to 250s before the door closes automatically. The default value is 3s.
Soft start and slow stop. There're soft start and slow stop features available. The distance and speed of the slow stop feature can be adjusted.
Stop & rebound against resistance. Switchable between stop against resistance and rebound against resistance for the closing travel. Stop against resistance for the opening travel.
Onboard socket for Bluetooth module. A socket is integrated onboard for the insertion of the standalone Bluetooth module (module not included by default).
One button configuration for internet control. Can be directly paired with the internet controllers through pressing one button onboard, no copy procedure is required.
Motor Basic Function |
24V DC motor and can working with backup batteris |
OEM Service |
OEM Logo and OEM Pakage |
Expansion Function |
Mob apps and encryption Remote |
The Control Board
Packing/Shipping
About us